Mileage
134,843
Service Date
4/24/2020
Services Performed
- AC gauge test. System 250/30 running pressure static pressure is about 110 psi. Compressor is noisy initially when it comes on. Duct temp is about 55 degrees. Recovered. 90lb r134a vacuumed the ystem down and recharged with 1lb.
- AIR CONDITIONING SYSTEM – Complete Charge – All Applicable Models – [Includes: Air Conditioning system recover, evacuate and recharge.]
- Engine tries to stall when a.c. disengages or when cooling fans cycle. Performed air induction service and pcm reset/idle relearn.
- Fuel injection andGREEN THROTTLE INDUCTION CLEANING
- Install oil filler flange oring
JAMES G. gave our service a 5 star review on 5/19/2020